1,100 Litres Short: How to Check Diesel Supply in Nigeria

How do you know your building received all the diesel it paid for? Learn how to check diesel supply, verify tanker deliveries and track generator consumption.

Share
Facility technician checking diesel levels in a storage tank beside a generator house and a diesel tanker.

A hotel in Port Harcourt ordered 20,000 litres of diesel and paid for it upfront. The tanker arrived, and offloading began. But when the team checked the tank afterwards, they discovered that 1,100 litres were missing.

They caught the shortage because they checked the tank before and after delivery. Read the reported incident here.

Now, imagine managing a hospital, office building or residential estate that depends on generators for electricity. With multiple deliveries and thousands of litres of diesel involved, how do you know you're getting everything you pay for?

For many facility managers, checking diesel deliveries is part of the job. The challenge is keeping proper records of what was ordered, what arrived, and how much the generators actually consumed.

Here are five practical steps to help your team check diesel supply and monitor generator consumption.

Quick answer: To check diesel supply, measure your storage tank before and after offloading, record the tanker meter readings and compare the figures with the delivery note. Use your tank's calibration chart to calculate the quantity received. Then track diesel stock and generator run hours weekly to monitor consumption.

Why is checking diesel supply important?

Diesel is a major operating expense for buildings that depend on generators. Hospitals, banks, hotels, and large residential estates can consume thousands of litres depending on their power requirements.

According to the National Bureau of Statistics, the average retail price of diesel reached ₦1,648.08 per litre in March 2026, up from ₦1,420.17 in February. That's a 16.05% increase, according to Nairametrics' report.

At ₦1,648.08 per litre, 1,100 litres would cost approximately ₦1.81 million.

That is a significant amount to lose without knowing where the difference came from.

Some common gaps in diesel management include:

  • Checking the tank only after offloading has started.
  • Failing to record tanker meter readings.
  • Signing delivery notes for the quantity ordered rather than received.
  • Keeping generator run hours and fuel records separately.
  • Having no consistent process for comparing diesel deliveries with actual consumption.

Without proper records, it becomes difficult to identify shortages, investigate unusual consumption, or understand the true cost of running a generator.

How to check diesel supply in 5 steps

Checking diesel supply should be part of your normal delivery process. Here is how your facility team can do it.

1. Measure the tank before delivery

Before the tanker starts offloading, use a dipstick to check the current diesel level in your storage tank.

Record the reading, date, and time, and take a photograph for reference. Use the same dipstick and measurement method each time.

Also make sure no diesel is being drawn from the tank during the measurement process. This helps ensure that your readings accurately reflect the delivery.

2. Check the tanker meter and waybill

Before and after offloading, record the tanker meter readings and take photographs.

Compare the difference with the quantity stated on the waybill. For example, if your order is for 5,000 litres, you should be able to verify the quantity recorded by the tanker meter.

Remember, the waybill shows what was ordered or declared for delivery. It does not automatically confirm what entered your storage tank.

3. Monitor the offloading process

Where possible, have two members of staff from different teams present during delivery.

One can monitor the offloading while the other records the readings and checks the documents.

Make sure the tanker and delivery details match your order. Your team should also follow the site's approved fuel-handling and safety procedures.

4. Measure the tank after delivery

Once offloading is complete, allow the diesel to settle before taking another reading.

Use the same dipstick and photograph the new level. Your tank's calibration chart will help you convert the measurement into litres.

For example:

  • Opening tank stock: 4,000 litres
  • Closing tank stock: 8,800 litres
  • Quantity received: 4,800 litres
  • Quantity stated on the waybill: 5,000 litres

There is a 200-litre difference that needs to be investigated.

Before concluding that the delivery was short, check that the readings were taken correctly, no fuel was used during offloading, and the calibration chart is accurate.

5. Record what was actually received

Compare the quantity measured with the quantity on the waybill.

If there is a difference, document it before the tanker leaves. Keep the photographs, meter readings, and delivery documents together.

This gives your team something concrete to refer to when discussing the discrepancy with the supplier.

How to track generator diesel consumption weekly

Checking deliveries is only half the job. You also need to know how much diesel your generators consume.

A simple weekly record should include:

  • Opening stock: the litres available at the beginning of the week.
  • Diesel delivered: the quantity received during the week.
  • Closing stock: the litres remaining at the end of the week.
  • Generator run hours: the total operating hours recorded on the hour meter.

Use this formula:

Diesel consumed = Opening stock + Deliveries − Closing stock

Then calculate average consumption:

Litres per hour = Diesel consumed ÷ Generator run hours

For example, if a building starts the week with 4,000 litres, receives 10,000 litres and ends with 9,200 litres, the generator has consumed 4,800 litres.

If it ran for 120 hours, its average consumption is 40 litres per hour.

Compare this with previous weeks under similar operating conditions. If consumption suddenly increases, investigate possible leaks, changes in generator load, maintenance issues, or other operating conditions.

If multiple generators share one tank, use separate fuel issue records or suitable metering to establish individual generator consumption.

How do you manage diesel across multiple buildings?

For organisations managing properties in Lagos, Abuja and Port Harcourt, keeping diesel records across different locations can become complicated.

Each building may have different generators, operating hours, fuel deliveries and expenses.

The best approach is to standardise the reporting process across all locations. Every site should record its diesel deliveries, tank readings, generator run hours, consumption and expenses.

Management can then compare the figures weekly and identify locations where fuel consumption or operating costs have changed.

You can also explore useful templates and checklists on the Casalink resources page.

Keeping records in notebooks, spreadsheets and WhatsApp conversations can make it difficult to see the full picture.

Casalink helps facility teams organise their operational records in one place.

Your team can:

  • Record tank dips, meter readings and generator run hours.
  • Keep delivery information and supporting photographs.
  • Monitor generator consumption and maintenance history.
  • Compare energy costs across diesel, gas, solar and grid supply where the required data is available.
  • Manage planned servicing and maintenance activities.
  • Access operational records across multiple properties.

Your facility team still carries out the physical checks. Casalink helps organise the information so managers can review the figures and make better operational decisions.

Explore our guides on maintenance request tracking and estate management software.

Keep track of every diesel delivery

If your building depends on generators, start by reviewing one recent diesel delivery.

Compare the waybill, tank readings, and generator run hours. Do the figures add up? Can your team easily retrieve the records?

Casalink helps facility teams keep these operational records organised across their buildings.

Frequently asked questions

How do I know if my diesel supply is short?

Measure the tank before and after offloading, then compare the difference in litres with the tanker meter and waybill. Make sure no fuel was used during the measurement period. Document any unexplained difference with photographs and readings.

How do you measure diesel in a storage tank?

Use a clean dipstick to measure the fuel level. Then use the tank's calibration chart to convert the reading into litres. Use the same dipstick and method for consistent measurements.

How many litres of diesel does a generator use per hour?

It depends on the generator's capacity, electrical load, condition, and efficiency. You can calculate actual consumption by dividing the litres used by the generator's run hours.

Can I track generator diesel consumption without fuel sensors?

Yes. Start with a dipstick, tank calibration chart, delivery records, and generator hour meter. Record the figures consistently and compare consumption every week.

How often should I check diesel deliveries?

Check every delivery when it arrives. Record the tank level before and after offloading, compare the tanker meter with the waybill, and review generator consumption weekly.

What is diesel reconciliation?

Diesel reconciliation is the process of comparing opening stock, deliveries, fuel consumed, and closing stock. It helps facility teams identify unexplained differences and monitor generator fuel usage.